Startup and shutdown
To start the drive:
1. Turn the speed adjust potentiometer full counterclockwise
(CCW), or set the voltage signal to zero.
2. Apply DC voltage input.
3. Slowly advance the speed adjust potentiometer clockwise (CW),
or increase the voltage signal. The motor slowly accelerates as
the potentiometer is turned CW or the voltage signal is
increased. Continue until the desired speed is reached.
4. Remove DC voltage input from the drive to coast the motor to a
stop.
If the motor or drive does not perform as described, disconnect the
DC voltage input immediately. Refer to the Troubleshooting section
(page 33) for further assistance.
16