Leeson NEMA 4X SCR Control: 174903.00 (Obsolete) Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Oprogramowanie Leeson NEMA 4X SCR Control: 174903.00 (Obsolete). LEESON NEMA 4X SCR Control: 174903.00 (Obsolete) User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 19
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
SPEEDMASTER
Variable Speed
D.C. Control
INSTRUCTION MANUAL
TM
This Book Covers Speedmaster Control
Numbers 174902 & 174903
TM
LEESON ELECTRIC CORPORATION
GRAFTON, WI 53024-0241 U.S.A. TELEPHONE (262)377-8810 FAX (262)377-9025
Przeglądanie stron 0
1 2 3 4 5 6 ... 18 19

Podsumowanie treści

Strona 1 - LEESON ELECTRIC CORPORATION

SPEEDMASTERVariable SpeedD.C. ControlINSTRUCTION MANUALTMThis Book Covers Speedmaster ControlNumbers 174902 & 174903TMLEESON ELECTRIC CORPORATI

Strona 2 - TABLE OF CONTENTS

START-UP PROCEDURE9The trimpot adjustments, MIN, MAX, I.R. COMP, and CUR LIM are checked at the factory usinga typical motor at 240 VAC input. Use the

Strona 3

10TRIMPOT FUNCTION ADJUSTMENT1. TURN DRIVE POWER OFF!!2. Connect DC Voltmeter: + to +ARM, - to -ARM.3. Set meter voltage range: (90VDC or 180VDC).4. T

Strona 4 - COMMONLY ASKED QUESTIONS

1/41/31/23/41.01/41/23/41.01.52.0MIN MAX ACCEL I.R. C.L. H.P.1/8INPUTVOLTAGEOUTPUTVOLTAGE120VAC120VAC120VAC120VAC120VAC240VAC240VAC240VAC240VAC240VAC2

Strona 5 - CONTROL FEATURES

The Common of the SPDT switch is connected tocontrol pot HI and is switched between SpeedpotHi and the Inhibit pin (P2). To inhibit (stop motor),speed

Strona 6 - MOUNTING

13SPEEDPOT(5K 2W)CUSTOMER'SMOUNTING BRACKETDIALPLATE2.00" dia.LOCK WASHERO-RINGHEX NUTSPEEDPOTKNOB.4373/8DIA.5/32 DIA.SPEEDPOT LOCATOR HOLE

Strona 7 - CUSTOMER FUSING

14Motor doesn't operateMotor stalls, or runsvery slowly with speed-pot turned fully CWMotor huntsRepeated fuse blowingMotor runs but will notstop

Strona 8 - TERMINAL STRIP WIRING

15SPECIFICATIONSAC input voltage... ±10% of rated line voltageAcceleration...

Strona 9 - AC INPUTARM INPUT

16C7SPEEDMASTER PARTS PLACEMENT & LISTRESISTORSCAPACITORSMISCELLANEOUSDIODESR1R2R3R4R5R6R7R8R9R10R11R12R13R14R15R16R17R18R19R20R21R22R23R24R25R26R

Strona 10 - ADJUSTMENTS

SPEEDMASTER SCHEMATICALL RESISTORS 1/2W UNLESS NOTED OTHERWISEQ2 ... 3052 MOCQ3, Q4, D5, D6, D7 ... L512FY131 GENTR

Strona 12

TABLE OF CONTENTSWARRANTY ...

Strona 13 - CONTROL MODIFICATIONS

LIMITED WARRANTYA. WARRANTY: LEESON Electric Corporation warrants that their products will be freefrom defects in material and workmanship for a peri

Strona 14 - MAINTENANCE PROCEDURE

INTRODUCTION3Q. CAN I RUN TWO OR MORE MOTORS FROM THE SAME DRIVE?A. Not recommended. The IR Comp (regulation) and Current Limit would have problemssen

Strona 15 - IN CASE OF DIFFICULTY

CONTROL FEATURES4MIN. SPEED (minimum speed) - Allows adjustment of the motor speed when the speedpotis set at minimum (CCW). This permits the user to

Strona 16 - TYPICAL MOTOR CURRENTS

DIMENSIONS5Allow 3.50" for height clearance, 7.40" for overall length.WARNING1. Be sure the control housing is properly grounded.2. Arm conn

Strona 17 - ACTIVE DEVICES

MODEL SELECTION6The Speedmaster will operate a 90 VDC motor in the H.P. range of 1/8 through 1 H.P., and a180 VDC motor in the range of 1/4 through 2

Strona 18 - SPEEDMASTER SCHEMATIC

TERMINAL STRIP WIRINGThe Speedmaster has an 11 position block type terminal strip for ease of connection.P1-1(SPEEDPOT LO) Connects to low side (orang

Strona 19 - Bulletin #301 12/00

SPEEDMASTER MODEL 174902 HOOK-UP DIAGRAM8SPEEDMASTER MODEL 174903 HOOK-UP DIAGRAMBEFORE SCREWING DOWN COVER ASSEMBLY, ROUTE WIRING THROUGH CONDUIT HOL

Komentarze do niniejszej Instrukcji

Brak uwag