Leeson Chassis Mount PWM Control: M1740009.00 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Oprogramowanie Leeson Chassis Mount PWM Control: M1740009.00. LEESON Chassis Mount PWM Control: M1740009.00 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - USER’S MANUAL

USER’S MANUALM1740009.OOPulse-Width Modulated, Adjustable SpeedDrives for DC Brush Motors

Strona 2 - LIMITED WARRANTY

4 InstallationWiring• Use 18 AWG wire for speed adjust potentiometer wiring.Use 16 AWG wire for motor and AC line voltage wiring.• Twist logic wires (

Strona 3 - Safety Warnings

5InstallationLine fuseThe M1740009.00 drive is protected by a 5A, 250V AC linefuse. The fuse does not have to be resized as long as themotor used is

Strona 4 - Contents

6 InstallationSpeed adjust potentiometerMount the speed adjust potentiometer through a 0.38 in.(10 mm) hole with the hardware provided (see Figure 3).

Strona 5

7InstallationQuick-connect terminal blockThe quick-connect terminal block has an 8-pin header blockand 8-screw terminal plug (Figure 4). To use the q

Strona 6 - Illustrations

8 InstallationConnectionsAssumptions: This drive series supplies motor voltagefrom its A1 and A2 terminals. It is assumed throughout thismanual that

Strona 7 - Specifications

9InstallationL1 L2 A1 A2 S3 S20 - 5 VDCISOLATED VOLTAGESIGNAL INPUT+-S1H2H1Figure 6. Voltage Follower ConnectionsVoltage followerInstead of using a s

Strona 8 - Dimensions

10Note: Before applying power, verify that no conductivematerial is placed on the printed circuit board.To start the drive:1. Turn the speed adjust

Strona 9 - Installation

11OperationThis drive is equipped with two diagnostic LEDs: powerstatus (PWR) and current limit mode (CUR LIM). SeeFigure 7 for LED locations.POWER

Strona 10 - 4 Installation

12 OperationLine starting and stopping (applying and removing AC linevoltage) is recommended for infrequent starting andstopping of a drive only. Whe

Strona 11 - Line fuse

13OperationA 1 Ohm, 1 W resistoris used as the dynamicbrake resistor. Formotors rated 1/17horsepower and lower,a dynamic brakeresistor is notnecessar

Strona 12 - Speed adjust potentiometer

LIMITED WARRANTYA. Warranty - LEESON Electric warrants that its products will be free from defects inmaterial and workmanship for a period of one (1)

Strona 13 - TERMINAL

14The MIN SPD setting determines the motor speed when thespeed adjust potentiometer is turned full CCW. It is factoryset for zero speed.To calibrate,

Strona 14 - Connections

15CalibrationThe IR COMP setting determines the degree to which motorspeed is held constant as the motor load changes. It isfactory calibrated for a

Strona 15 - Voltage follower

16 Calibration3. Lock the motor armature. Be sure that the motor is firmlymounted.4. Connect power to the drive. The motor should remainstopped.5.

Strona 16 - Operation

17S3S2S1R1R2R4TOTALSERIESRESISTANCE10KOHMSR3Figure 11. Multiple Fixed SpeedsReplace the speed adjust potentiometer with seriesresistors with a total

Strona 17 - LIMIT LED

18 Application NotesCWS3S2S1CW5KOHM5KOHMHIGHSPEEDLOWSPEEDFigure 12. Adjustable Fixed Speeds UsingPotentiometers in SeriesReplace the speed adjust pot

Strona 18 - Line starting and stopping

19Application NotesS3S2S1SPEED1SPEED220KOHMCWCW20KOHMFigure 13. Independent Adjustable SpeedsReplace the speed adjust potentiometer with a single pol

Strona 19 - Figure 8. Inhibit Switch

20 Application Notescw10K ohmSpeed PotRUNJOGJOGPUSHBUTTONFigure 14. RUN/JOG Switch ConnectionUsing a RUN/JOG switch is recommended in applicationswhe

Strona 20 - Calibration

21Application NotesMOTORFORWARDBRAKEREVERSEA2A1H2H11 Ohm 1 WDynamicBrake ResistorFigure 15. Reversing Circuit ConnectionA dynamic brake may be used w

Strona 21 - Regulation (IR COMP)

22WarningDangerous voltages exist on the drive when it ispowered. When possible, disconnect the AC linevoltage from the drive while troubleshooting.

Strona 22 - TORQUE (cont.)

23TroubleshootingMotor does not run1. Check for blown fuses or tripped circuit breaker.2. Verify that the speed adjust potentiometer is not set to z

Strona 23 - Multiple fixed speeds

iSafety Warnings• This symbol  denotes an important safety tip orwarning. Please read these instructions carefullybefore performing any of the proced

Strona 24 - Potentiometers in Series

24 TroubleshootingMotor will not stop when the speed adjust potentiometer is fullcounterclockwise1. Turn the MIN SPD trimpot CCW until the motor stop

Strona 25 - Independent adjustable speeds

25Block DiagramsS3 (H1)MAX/MINSPEEDCIRCUITPWMCIRCUITPOWERSWITCHINGCIRCUITIR COMPCIRCUITCURRENTLIMITCIRCUIT+VBUSPOWERBRIDGECIRCUITFU501S2S1 (H2)L1L2A1A

Strona 26 - 20 Application Notes

26L1S1 (H2)S2S3 (H1)BR501 GBU8J15V.5WP501100K3MAXSPDR13 300KR7 330KR12 330KR16330K86574V-V+IC2LM358NR15 330KR5026.8K/10W+15VR915K+5VMINSPDCW3C

Strona 29

29NOTES

Strona 30

2100 Washington StreetGrafton, WI 53024-0241, U.S.A.TEL: (262) 377-8810 FAX: (262) 377-9025Document number 250–0256, Rev. 1Printed in the U.S.A –

Strona 31 - Block Diagrams

iiContentsSafety Warnings iSpecifications 1Dimensions 2Installation 3Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 32

iiiContentsApplication Notes 17Multiple fixed speeds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Adjustable

Strona 33

ivIllustrationsFigure 1. M1740009.00 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2Figure 2.

Strona 34

1SpecificationsModel M1740009.00AC Line Voltage 115 VAC, ±10%, 50/60 Hz, single phaseHorsepower Range (with 130 VDC motors) 1/20 - 1/3 HPArmature Volt

Strona 35

2Figure 1. M1740009.00 DimensionsDimensions3.80 [97]MIN SPDNEGNEGIR COMPP503MAX SPDP501SO501R501R503FU501TH501C501C502KR502BR501 D501 Q501TORQUEP502I

Strona 36 - 2100 Washington Street

3• Protect the drive from dirt, moisture, and accidentalcontact. • Provide sufficient room for access to the terminal blockand calibration trimpots.•

Komentarze do niniejszej Instrukcji

Brak uwag